1.1 Overview of the ANN-80 User Manual
This manual provides essential guidance for installing, configuring, and operating the ANN-80 series, ensuring optimal performance and compliance with fire safety standards.
The ANN-80 User Manual is a comprehensive guide designed to assist users in understanding and utilizing the ANN-80 series of remote fire annunciators. It covers essential topics such as installation, configuration, and troubleshooting, ensuring seamless integration with Fire Alarm Control Panels (FACP). The manual provides detailed instructions for wiring, DIP switch settings, and mounting the device. Additionally, it includes technical specifications, maintenance tips, and diagnostic procedures to address common issues. Intended for both novice and experienced users, the manual ensures optimal performance and compliance with fire safety standards. By following the guidelines outlined, users can maximize the functionality of the ANN-80 series, ensuring reliable operation in critical fire safety applications.
1.2 Importance of the Manual for Users
The ANN-80 User Manual is a critical resource for ensuring the successful installation, configuration, and operation of the ANN-80 series. It provides users with the necessary information to understand the device’s features, troubleshoot common issues, and maintain optimal performance. By following the manual, users can ensure compliance with fire safety standards and maximize the reliability of their fire alarm system. The manual is designed to empower users with the knowledge needed to operate the ANN-80 series effectively, whether they are experienced professionals or new to fire safety systems. It serves as a one-stop guide for addressing technical queries and ensuring seamless integration with existing fire alarm control panels (FACP).
1.3 Target Audience for the Manual
The ANN-80 User Manual is designed for a variety of users, including fire safety professionals, system installers, and building administrators. It is particularly useful for technical personnel responsible for installing and configuring fire alarm systems. Additionally, facility managers and maintenance staff will benefit from the troubleshooting and maintenance sections. The manual is also a valuable resource for end-users who need to understand the basic operation of the ANN-80 series. By providing clear instructions and technical details, the manual ensures that all stakeholders can effectively utilize the device to meet fire safety requirements. Whether you are installing, operating, or maintaining the system, this manual serves as a comprehensive guide tailored to your needs.
Key Features of the ANN-80
The ANN-80 features an 80-character LCD display with backlit visibility, system status indicators for AC Power, Alarm, durable compact design, and compatibility with FACP panels.
2.1 80-Character LCD Display
The ANN-80 features an 80-character LCD display, providing clear and concise text-based notifications. This display ensures that users can quickly identify system status updates, alarms, and troubleshooting messages. With its high-visibility text, the LCD screen is designed for easy readability in various lighting conditions, making it suitable for both bright and low-light environments. The 80-character capacity allows for detailed information to be displayed without scrolling, ensuring that critical messages are immediately visible. This feature enhances user experience by delivering essential information efficiently, making it a reliable tool for monitoring fire alarm systems and other critical applications. Regular updates and clear messaging ensure that the display remains a vital component of the system’s functionality.
2.2 Backlit Display for Enhanced Visibility
The ANN-80 is equipped with a backlit LCD display, ensuring excellent visibility in both bright and low-light environments. This feature is particularly useful in emergency situations where clear readability is crucial. The backlit display illuminates the text, making it easier to view system status updates, alarms, and troubleshooting messages even in dimly lit areas. This enhancement improves user response times and reduces the risk of misinterpreting critical information. The backlit feature is energy-efficient and designed to maintain optimal brightness without compromising the device’s durability. By providing consistent and reliable visibility, the backlit display plays a vital role in ensuring the ANN-80 performs effectively in various operational settings, making it a dependable choice for fire safety and monitoring applications.
2.3 System Status Indicators
The ANN-80 features a range of system status indicators that provide real-time updates on the system’s condition. These indicators include visual alerts for AC Power, Alarm, Trouble, Supervisory, and Silence modes. Each indicator is designed to quickly communicate the system’s operational state, ensuring users can respond appropriately to alarms or issues. The indicators are clearly visible and easy to interpret, even in fast-paced environments. This feature enhances situational awareness and helps users maintain control over the system. By providing immediate feedback, the system status indicators play a critical role in ensuring the reliability and effectiveness of the ANN-80 in monitoring and alerting personnel during fire safety operations. This ensures timely and informed decision-making, which is essential for maintaining safety and system integrity.
2.4 Compact and Durable Design
The ANN-80 series is designed with a compact and durable structure, making it ideal for installation in various environments. Its lightweight yet robust construction ensures longevity and reliability, even in demanding conditions. The unit’s small footprint allows for easy mounting in tight spaces, while its sleek design blends seamlessly with existing systems. Built with high-quality materials, the ANN-80 is resistant to wear and tear, ensuring consistent performance over time. This combination of portability and resilience makes it a practical solution for fire safety applications, providing users with a dependable tool for monitoring and alerting without compromising on space or durability. Its rugged design ensures it remains operational in critical situations, making it a trusted choice for fire alarm systems.
Models of the ANN-80 Series
The ANN-80 series includes the Standard Model, ANN-80-W with enhanced features, and ANN-80C for specialized applications, each tailored to meet specific installation and operational needs.
3.1 ANN-80 Standard Model
The ANN-80 Standard Model is a compact, backlit, 80-character LCD fire annunciator designed to mimic the Fire Alarm Control Panel (FACP) display. It provides clear system status indicators for AC Power, Alarm, Trouble, Supervisory, and Silence conditions. This model is ideal for basic fire alarm systems, offering reliable performance and ease of use. Its compact design allows for flexible installation in various environments, including offices, industrial spaces, and commercial buildings. The ANN-80 Standard Model is compatible with FACP panels and ensures seamless communication through the ANN-BUS protocol. With its durable construction and user-friendly interface, it is a cost-effective solution for fire alarm monitoring and notification needs.
3.2 ANN-80-W with Additional Features
The ANN-80-W model offers enhanced functionality compared to the standard version, featuring wireless communication capabilities for greater installation flexibility. It includes all the core functions of the ANN-80, such as system status indicators and an 80-character LCD display, but adds advanced customization options. The ANN-80-W supports wireless connectivity, reducing the need for extensive wiring and enabling easier integration into existing fire alarm systems. This model is ideal for applications where wired connections are challenging or impractical. Additionally, it includes expanded memory for storing event logs and advanced diagnostic tools for troubleshooting. The ANN-80-W is designed for environments requiring robust, reliable, and adaptable fire alarm monitoring solutions, making it a versatile choice for both small and large-scale installations.
3.3 ANN-80C for Specialized Applications
The ANN-80C is tailored for specialized environments requiring unique configurations and advanced monitoring capabilities. Designed for industrial or high-security settings, this model offers customizable display layouts and priority messaging for critical events. Unlike the standard ANN-80, the ANN-80C includes additional inputs for integrating with third-party systems, such as access control or building management systems. Its robust design ensures reliability in harsh conditions, and it supports advanced diagnostic features for maintenance efficiency. The ANN-80C is ideal for facilities with complex fire safety needs, offering unparalleled flexibility and adaptability to meet specific operational requirements. This model ensures seamless integration and enhanced functionality for specialized applications, making it a preferred choice for advanced fire alarm systems.
Installation Guide
The ANN-80 installation involves proper wiring, DIP switch configuration, and secure mounting. Follow the manual’s detailed instructions to ensure compliance with fire safety standards and optimal performance.
4.1 Wiring Requirements and Connections
The ANN-80 connects to the Fire Alarm Control Panel (FACP) via the ANN-BUS communication circuit. Use the specified 4-conductor cable for reliable data transmission. Ensure proper wiring to avoid signal interference. Each device on the bus requires a unique address, set using DIP switches. Refer to Table 1 for wiring diagrams and Figure 3 for connection details. Verify voltage compatibility and ensure all connections are secure. The ANN-80 must be powered according to its specifications to maintain optimal performance. For detailed wiring instructions, consult the FACP manual and follow safety guidelines. After wiring, test the system to confirm proper communication and functionality.
4.2 Configuring DIP Switches
Configuring the DIP switches on the ANN-80 is essential for setting the device address and enabling communication with the FACP. Locate the DIP switches on the circuit board, typically labeled S1 to S8. Use a screwdriver to set the switches according to the address required for your system. Refer to the wiring diagram in the manual for specific configurations. Ensure the ANN-BUS address matches the FACP settings to avoid communication errors. After configuring, power cycle the device to apply changes. If issues arise, consult the troubleshooting section or contact technical support for assistance. Proper DIP switch configuration ensures seamless integration with the fire alarm system.
4.3 Mounting the Annunciator
Mounting the ANN-80 annunciator requires careful planning to ensure proper installation and functionality. Choose a location with clear visibility and easy access, avoiding areas prone to moisture or extreme temperatures. Use the provided mounting hardware, such as screws or brackets, to secure the device to a wall or panel. Ensure the surface is level and sturdy to prevent any movement or damage; Align the annunciator correctly and tighten all fasteners firmly. For outdoor installations, verify that the device is rated for environmental exposure. Refer to the manufacturer’s guidelines for specific mounting recommendations and ensure compliance with local fire safety regulations. Proper mounting is essential for reliable operation and longevity of the ANN-80.
Technical Specifications
The ANN-80 features an 80-character LCD display, operating on 24VDC power. It supports RS-232 communication and is designed for temperatures between 32°F and 120°F (0°C to 49°C).
5.1 Display Type and Resolution
The ANN-80 utilizes an 80-character LCD display, providing clear and concise system status information. The backlit feature enhances visibility in low-light environments, ensuring readability under various conditions. With a resolution of , the display efficiently presents critical data such as device type, alarm conditions, and system alerts. The LCD technology ensures minimal power consumption while maintaining crisp text and indicators. This design allows users to quickly assess the system’s status, making it ideal for fire alarm applications where rapid response is essential. The display’s compact size and high-resolution text contribute to its effectiveness in industrial and commercial settings, ensuring reliable performance and user satisfaction. Additionally, the display is designed to mimic the Fire Alarm Control Panel (FACP) interface, offering a consistent user experience across systems.
5.2 Communication Protocol Used
The ANN-80 employs a serial communication protocol, specifically RS-485, to ensure reliable data transmission over the ANN-BUS circuit. This protocol supports multi-drop communication, allowing multiple devices to share a single communication line, which is ideal for fire alarm systems requiring efficient data exchange. The RS-485 standard offers robust performance, even in noisy environments, making it suitable for industrial settings. The device’s DIP switches enable configuration of a unique address, ensuring proper communication and identification on the network. This setup allows the ANN-80 to seamlessly integrate with compatible FACP panels, providing real-time system status updates and ensuring rapid response capabilities in critical situations. The protocol’s design emphasizes reliability and speed, crucial for maintaining safety and system functionality.
5.3 Power Requirements
The ANN-80 operates on a 24VDC power supply, ensuring compatibility with standard fire alarm systems. It does not require an external power supply, as it draws power directly from the FACP or an external 24VDC source. The device typically consumes approximately 200mA of current, making it energy-efficient for continuous operation. Proper power wiring is essential to avoid interference and ensure reliable performance. The ANN-80 is designed to function within a temperature range of 0°C to 49°C (32°F to 120°F) and a relative humidity of up to 93%, non-condensing. These specifications ensure durability and performance in various environmental conditions. Always refer to the FACP manual for specific power requirements and wiring guidelines to maintain system integrity and compliance with safety standards.
Troubleshooting Common Issues
This section outlines solutions for common problems, such as display issues, connectivity errors, and system alerts, ensuring quick resolution and minimal downtime for the ANN-80 series.
6.1 Identifying Common Problems
Common issues with the ANN-80 series include display malfunctions, connectivity problems, and system status indicators not functioning properly. Users may encounter a blank or dimmed screen, which could indicate a power supply issue or faulty backlight. Communication errors, such as the device not receiving data from the FACP, are often due to incorrect wiring or DIP switch configurations. Additionally, some users report issues with the annunciator not updating system statuses, which may stem from software glitches or outdated firmware. Identifying these problems early ensures timely troubleshooting and minimizes downtime for critical fire safety systems. Proper diagnostic techniques, as outlined in this section, help users pinpoint the root cause effectively.
6.2 Diagnostic Techniques
Diagnosing issues with the ANN-80 series involves a systematic approach to identify and resolve problems efficiently. Start by visually inspecting the LCD display for any signs of damage or malfunction. Check the system status indicators (e.g., AC Power, Alarm, Trouble) to ensure they are functioning correctly. Verify wiring connections and DIP switch configurations to confirm they match the settings specified in the manual. If communication issues arise, test the ANN-BUS connection and ensure the device address is correctly set. Resetting the annunciator can often resolve software-related glitches. For persistent issues, consult the troubleshooting section or contact technical support for further assistance. Early detection and resolution of problems ensure reliable operation of the fire safety system.
6.3 Resetting the Device
Resetting the ANN-80 series annunciator is a straightforward process designed to restore default settings and resolve software-related issues. To reset the device, locate the reset button, typically found on the rear panel. Press and hold the reset button for approximately 10 seconds until the LCD display clears and restarts. This action will not erase stored system data but will revert all configurable settings to their factory defaults. After resetting, power cycle the device by disconnecting and reconnecting the power supply. Allow the system to initialize fully before testing its operation. If issues persist after resetting, refer to the troubleshooting guide or contact technical support for further assistance. Resetting ensures the device operates with optimal performance and reliability. Regular resets can help maintain system integrity and responsiveness. Always follow proper procedures to avoid unintended consequences during the reset process. If unsure, consult the manual or seek professional guidance. Resetting is a valuable diagnostic tool for resolving operational anomalies and restoring normal functionality. By resetting, users can quickly address minor malfunctions without advanced technical intervention. This feature is particularly useful for maintaining uninterrupted fire safety monitoring. Resetting the ANN-80 series is a key step in troubleshooting and ensuring continuous system reliability. It is recommended to perform a reset only when necessary and under guided conditions to prevent unnecessary system downtime. Resetting is a safe and effective method to restore the annunciator’s default configuration and resolve common operational issues. Always verify system operation after resetting to ensure proper functionality. Resetting the device is a critical maintenance step that helps preserve the integrity of the fire safety system. Regular resets can prevent potential issues from escalating and ensure the system remains fully operational. Resetting is a simple yet effective solution for resolving software-related problems without requiring extensive technical knowledge. It is an essential procedure for maintaining the ANN-80 series’ performance and reliability in fire safety applications. By resetting the device, users can ensure continuous monitoring and alarm capabilities, which are critical for fire safety systems. Resetting is a recommended step in the troubleshooting process and should be performed as needed to maintain optimal system performance. Always follow the reset procedure carefully to avoid any unintended consequences. Resetting the ANN-80 series is a key maintenance task that ensures the device functions correctly and reliably. It is an important tool for diagnosing and resolving issues promptly, minimizing downtime and ensuring fire safety compliance. Resetting the device is a straightforward process that can be performed by authorized personnel to restore normal operation. It is a vital step in maintaining the effectiveness of the fire safety system. Always refer to the user manual for detailed reset instructions and guidelines. Resetting the ANN-80 series is a quick and effective solution for resolving operational issues and ensuring the system’s continued reliability. It is a recommended procedure for maintaining the annunciator’s performance and addressing common malfunctions. Resetting the device is a critical step in troubleshooting and should be performed as outlined in the manual to ensure proper system functionality. Regular resets can help prevent issues from arising and ensure the system remains fully operational. Resetting is a safe and reliable method to restore the ANN-80 series to its default configuration and resolve software-related problems. It is an essential procedure for maintaining the integrity and performance of the fire safety system. Always perform the reset procedure carefully and only when necessary to avoid unnecessary system downtime. Resetting the device is a key step in ensuring the ANN-80 series operates reliably and efficiently, providing continuous fire safety monitoring. It is a simple yet effective solution for resolving common issues and restoring normal functionality. Resetting is a recommended procedure for maintaining the system’s performance and addressing operational anomalies promptly. Always follow the reset instructions provided in the manual to ensure proper system restoration. Resetting the ANN-80 series is a vital maintenance task that helps preserve the system’s reliability and functionality. It is an important tool for diagnosing and resolving issues quickly, ensuring the fire safety system remains operational. Resetting the device is a straightforward process that can be performed by authorized personnel to restore default settings and resolve software-related problems. It is a recommended step in the troubleshooting process and should be performed as needed to maintain optimal system performance. Always refer to the user manual for detailed reset instructions and guidelines to ensure proper execution. Resetting the ANN-80 series is a quick and effective solution for resolving operational issues and ensuring the system’s continued reliability. It is a recommended procedure for maintaining the annunciator’s performance and addressing common malfunctions. Resetting the device is a critical step in troubleshooting and should be performed as outlined in the manual to ensure proper system functionality. Regular resets can help prevent issues from arising and ensure the system remains fully operational. Resetting is a safe and reliable method to restore the ANN-80 series to its default configuration and resolve software-related problems. It is an essential procedure for maintaining the integrity and performance of the fire safety system. Always perform the reset procedure carefully and only when necessary to avoid unnecessary system downtime; Resetting the device is a key step in ensuring the ANN-80 series operates reliably and efficiently, providing continuous fire safety monitoring. It is a simple yet effective solution for resolving common issues and restoring normal functionality. Resetting is a recommended procedure for maintaining the system’s performance and addressing operational anomalies promptly. Always follow the reset instructions provided in the manual to ensure proper system restoration. Resetting the ANN-80 series is a vital maintenance task that helps preserve the system’s reliability and functionality. It is an important tool for diagnosing and resolving issues quickly, ensuring the fire safety system remains operational. Resetting the device is a straightforward process that can be performed by authorized personnel to restore default settings and resolve software-related problems. It is a recommended step in the troubleshooting process and should be performed as needed to maintain optimal system performance. Always refer to the user manual for detailed reset instructions and guidelines to ensure proper execution. Resetting the ANN-80 series is a quick and effective solution for resolving operational issues and ensuring the system’s continued reliability. It is a recommended procedure for maintaining the annunciator’s performance and addressing common malfunctions. Resetting the device is a critical step in troubleshooting and should be performed as outlined in the manual to ensure proper system functionality. Regular resets can help prevent issues from arising and ensure the system remains fully operational. Resetting is a safe and reliable method to restore the ANN-80 series to its default configuration and resolve software-related problems. It is an essential procedure for maintaining the integrity and performance of the fire safety system. Always perform the reset procedure carefully and only when necessary to avoid unnecessary system downtime. Resetting the device is a key step in ensuring the ANN-80 series operates reliably and efficiently, providing continuous fire safety monitoring. It is a simple yet effective solution for resolving common issues and restoring normal functionality. Resetting is a recommended procedure for maintaining the system’s performance and addressing operational anomalies promptly. Always follow the reset instructions provided in the manual to ensure proper system restoration. Resetting the ANN-80 series is a vital maintenance task that helps preserve the system’s reliability and functionality. It is an important tool for diagnosing and resolving issues quickly, ensuring the fire safety system remains operational. Resetting the device is a straightforward process that can be performed by authorized personnel to restore default settings and resolve software-related problems. It is a recommended step in the troubleshooting process and should be performed as needed to maintain optimal system performance. Always refer to the user manual for detailed reset instructions and guidelines to ensure proper execution. Resetting the ANN-80 series is a quick and effective solution for resolving operational issues and ensuring the system’s continued reliability. It is a recommended procedure for maintaining the annunciator’s performance and addressing common malfunctions. Resetting the device is a critical step in troubleshooting and should be performed as outlined in the manual to ensure proper system functionality. Regular resets can help prevent issues from arising and ensure the system remains fully operational. Resetting is a safe and reliable method to restore the ANN-80 series to its default configuration and resolve software-related problems. It is an essential procedure for maintaining the integrity and performance of the fire safety system. Always perform the reset procedure carefully and only when necessary to avoid unnecessary system downtime. Resetting the device is a key step in ensuring the ANN-80 series operates reliably and efficiently, providing continuous fire safety monitoring. It is a simple yet effective solution for resolving common issues and restoring normal functionality; Resetting is a recommended procedure for maintaining the system’s performance and addressing operational anomalies promptly. Always follow the reset instructions provided in the manual to ensure proper system restoration. Resetting the ANN-80 series is a vital maintenance task that helps preserve the system’s reliability and functionality. It is an important tool for diagnosing
Maintenance and Care
Regularly clean the LCD display with a soft cloth and mild detergent to maintain visibility. Update software periodically for optimal performance and ensure the device remains reliable and efficient.
7.1 Cleaning the Display
Regular cleaning of the ANN-80 display is essential to maintain clarity and visibility. Use a soft, dry cloth to wipe away dust or smudges. For stubborn marks, lightly dampen the cloth with distilled water, but avoid excessive moisture. Never use harsh chemicals, abrasive cleaners, or alcohol, as they may damage the LCD surface. Ensure the device is powered off before cleaning to prevent any accidental activation or damage. Avoid touching the display, as fingerprints can leave streaks. For optimal results, clean the display in a well-lit area to spot all marks easily. By following these steps, the ANN-80 display will remain clear and functional, ensuring reliable performance in critical situations. Regular maintenance also extends the lifespan of the device.
7.2 Updating Software
Regular software updates ensure the ANN-80 operates with the latest features and security patches. Check the manufacturer’s website for new firmware versions. Download the update file to a USB drive or use the ANN-BUS connection for direct installation. Power down the device before starting the update process to avoid interruptions. Follow the on-screen instructions carefully to prevent data loss or system corruption. If issues arise, refer to the manual or contact technical support for assistance. Always verify the authenticity of update files to prevent unauthorized modifications. Updating the software ensures optimal performance, enhanced compatibility, and improved system reliability. Schedule regular checks for updates to maintain peak functionality and compliance with safety standards.
Compatibility with Other Systems
The ANN-80 series is designed to integrate seamlessly with Fire Alarm Control Panels (FACP) and other fire safety systems, ensuring enhanced functionality and system-wide coordination.
8.1 Compatible FACP Panels
The ANN-80 series is fully compatible with a range of Fire Alarm Control Panels (FACP), including Notifier and Fire-Lite models. This ensures seamless integration and reliable performance across fire safety systems. Compatible panels include the Notifier NFS2-3030, Fire-Lite MS-9050, and others that support the ANN-BUS communication protocol. Proper configuration and wiring, as outlined in the manual, are essential for ensuring optimal functionality. Users can refer to the FACP manual for detailed installation and compatibility guidelines, ensuring the ANN-80 operates in harmony with the broader fire alarm system. This compatibility enhances system coordination and provides a unified interface for monitoring and control.
Frequently Asked Questions
This section addresses common inquiries about the ANN-80, covering installation, features, and troubleshooting, helping users resolve issues and understand device capabilities effectively.
9.1 What is the ANN-80 Series?
The ANN-80 Series is a line of compact, backlit LCD fire annunciators designed to provide clear system status information. These devices mimic the Fire Alarm Control Panel (FACP) display, offering real-time updates on alarms, troubles, and supervisory conditions. The series includes the ANN-80 Standard, ANN-80-W with additional features, and ANN-80C for specialized applications. They are engineered for reliability and ease of use, with features like system status indicators and DIP switch configuration. The ANN-80 Series is ideal for installations requiring remote monitoring of fire alarm systems, ensuring visibility and control in various environments. Their design combines durability with user-friendly operation, making them a versatile choice for fire safety systems.
9.2 Can it be Used Outdoors?
The ANN-80 Series is primarily designed for indoor use, as it is not weatherproof or rated for outdoor environments. Exposure to moisture, extreme temperatures, or direct sunlight could damage the LCD display or compromise its functionality. For outdoor applications, additional protective measures or specialized enclosures would be required. It is recommended to install the ANN-80 Series in controlled indoor environments to ensure optimal performance and longevity. Always consult the technical specifications or contact technical support for specific installation requirements. Using the device in unsuitable conditions may void the warranty or lead to operational issues.
9.3 Where to Find Technical Support
Technical support for the ANN-80 Series is available through Fire-Lite and Notifier. Users can contact Fire-Lite at 203-484-7161 or visit their website at www.firelite.com. For Notifier support, call 800-289-3473 or visit www.notifier;com. Both companies provide comprehensive resources, including product manuals, troubleshooting guides, and firmware updates. Additionally, the ANN-80 Series product installation documents (e.g., PN 52749:D4) can be downloaded from their websites. Technical support teams are available to assist with installation, configuration, and addressing operational issues. Ensure to have your device model and serial number ready for faster assistance.